  • 1.png

韩国TESCOM RF屏蔽箱

所属分类:

TESCOM

产品编号:

TC-5910D/5915A/5916A/5921A/5922


  • 产品介绍
  • 产品参数
  • TESCOM Shield Box

    With wide frequency band supporting range from 100 to 6000 MHz, the TESCOM Shield Box can be applied to most of the current and future wireless communication technologies such as GSM, WCDMA, WiMAX, LTE, GNSS, Bluetooth, and Wi-Fi. Therefore, the Shield Box can be used for mobile device measurement using multi-frequency bands without limitations and is ideal for mobile device measurement by maintaining stable and effective shielding performance in all frequency bands.

    Key Features

    • Supports wide frequency band of 100 ~ 6000 MHz
    • Applicable to all types of mobile phone measurement such as 2G, 3G, and 4G
    • Applicable to wireless communication device measurement such as GPS/GLONSAS, Bluetooth, Wi-Fi, WiMAX, and LTE
    • Provides various I/O interfaces
    • Excellent shielding performance Solid structure and exceptional durability
    • RS-232C control for automation

    Excellent Shielding Performance

    The most important feature of the Shield Box is the shielding of external interference signals that can be delivered to DUT. Depending on the measurement locations and testing environment, various signal interferences occur such as surrounding DUT signal, base station signal, and another measuring device′s signal, distorting the testing signal and lowering the reliability of measurement. However, the TESCOM Shield Box has secured stable shielding performance by using shield gasket and EMI filter in areas vulnerable to external interference signals such as I/O connectors, joints, and around doors.

    Application of Internal Electromagnetic Wave Absorber

    In case of radiation testing environment using RF coupler for DUT connection inside a shield box, some problems may occur such as internal reflection, standing waves caused by scattered EM waves, and changes in transmitter characteristics and DUT antenna impedance. By using a powerful electromagnetic wave absorber to reduce the reflection and scattering of EM waves, the TESCOM Shield Box offers a stable EM wave environment despite its small footprint.

    Exceptional Durability

    Because a shield box must perform repetitive opening and closing operations for several to thousands of times daily, its high durability is required. By using materials resistant to shock and corrosion, high-performance cylinder, and its related parts, the TESCOM Shield Box boasts of nearly zero likelihood of deformation; it is designed to maintain its performance despite more than a million operations.

    Antenna Coupler and Fixture

    When a shield box is used, DUT is connected by directly using cable or an antenna coupler. If interface for cable connection to DUT is available, the direct connection method is used; otherwise, a radiation measurement method with an antenna coupler is used. Since the results of radiation measurement change depending on the location of DUT, its fixture should maintain constant measurement conditions for repetitive measurements. TESCOM offers flexible fixtures that can change the location of the DUT fixture block. Depending on the shape of DUT, users can create its own fixture using two fixture blocks within seconds. Moreover, customized fixtures that meet the demands of customers can be manufactured and supplied if necessary. The various types of antenna coupler options with fixtures allow optimal measurement environment configuration that fits the characteristics of each DUT.

    F59105A + TC-93026A+ TC-5910D

    F59161A + TC-93026A + TC-5916A

    Provides Various I/O Interfaces

    To meet various customer demands, TESCOM Shield Box interface panels are offered in the form of module. Customers can combine and order the necessary I/O interfaces for measurement. EMI filter is applied to all data interfaces to prevent signal leak.

    I/O InterfaceOrder NumberData Speed / Line Voltage* Shielding Effects

    DB37, 1000pF pi Filter 3409-0012-1
    • 3 Mbps / 100 VDC,
    • 5 Amps max
    • > 70 dB from 0.5 to 2 GHz
    • > 80 dB from 2 to 3 GHz
    • > 70 dB from 3 to 6 GHz
    DB25, 1000pF pi Filter 3409-0009-1
    • 3 Mbps / 100 VDC,
    • 5 Amps max
    • >70 dB from 0.5 to 2 GHz
    • >80 dB from 2 to 3 GHz
    • >70 dB from 3 to 6 GHz
    DB25, 100pF pi Filter 3409-0014-1
    • 10 Mbps / 100 VDC,
    • 5 Amps max
    • > 50 dB from 0.5 to 2 GHz
    • > 60 dB from 2 to 3 GHz
    • > 60 dB from 3 to 6 GHz
    DB9, 1000pF pi Filter 3409-0008-1
    • 3 Mbps / 100 VDC,
    • 5 Amps max
    • > 70 dB from 0.5 to 2 GHz
    • > 80 dB from 2 to 3 GHz
    • > 70 dB from 3 to 6 GHz
    DB9, 100pF pi Filter 3409-0010-1
    • 10 Mbps / 100 VDC,
    • 5 Amps max
    • > 50 dB from 0.5 to 2 GHz
    • > 60 dB from 2 to 3 GHz
    • > 60 dB from 3 to 6 GHz
    USB 2.0 Filter 3409-0018A-3
    • 480 Mbps / 5 V, 500 mA /
    • Max Current: 5A
    • > 60 dB from 0.5 to 2 GHz
    • > 70 dB from 2 to 3 GHz
    • > 70 dB from 3 to 6 GHz
    USB 3.0 Filter(Active) 3409-0042A-1
    • 5000 Mbps / 5 V, 900 mA /
    • Max Current: 1.5 A
    • > 70 dB from 0.5 to 2 GHz
    • > 70 dB from 2 to 3 GHz
    • > 55 dB from 3 to 6 GHz
    RJ-45 Filter 3409-0022A
    • 1 Gbit/s Copper-Line
    • Ethernet (1000 BASE-T)
    • > 60 dB from 0.5 to 2 GHz
    • > 70 dB from 2 to 3 GHz
    • > 70 dB from 3 to 6 GHz

    DC Power Adaptor

    3406-0004A
    • 50 VDC,
    • 3 Amps max
    • > 70 dB from 0.5 to 2 GHz
    • > 80 dB from 2 to 3 GHz
    • > 80 dB from 3 to 6 GHz
    DC Power Adaptor,
    Banana Jack Type
    3406-0005A
    3406-0006A
    • 50 VDC,
    • 10 Amps max
    • > 70 dB from 0.5 to 2 GHz
    • > 80 dB from 2 to 3 GHz
    • > 80 dB from 3 to 6 GHz
    AC Power Adaptor 3103-0009A
    • 250 VAC,
    • 7 Amps max
    • > 70 dB from 0.5 to 2 GHz
    • > 80 dB from 2 to 3 GHz
    • > 80 dB from 3 to 6 GHz
    RF, N-SMA Connector 3408-0038  
    • > 60 dB from 0.5 to 2 GHz
    • > 70 dB from 2 to 3 GHz
    • > 70 dB from 3 to 6 GHz

    RF, SMA-SMA Connector

    3408-0039
       
    • > 60 dB from 0.5 to 2 GHz
    • > 70 dB from 2 to 3 GHz
    • > 70 dB from 3 to 6 GHz

     

    Expected shielding effects of the Shield Box if the appropriate interface is applied.

    Shield Box Selection Guide

    Selecting a Shield Box can largely depend on the size of DUT, connection methods, and measurement purpose. In general, customers need to consider the following prior to selecting a Shield Box:

    Shield Box operation methods

    Depending on the operation methods, there are two types of Shield Box: manual and pneumatic. For development and quality control, repetitive opening and closing operations are not necessary; therefore, the manual type is appropriate. For places requiring repetitive operations, remote control using PC programs, and automation such as production lines, however, a pneumatic type of Shield Box is the better choice.

    Shield Box sizes

    Select a Shield Box depending on the DUT size. If an antenna coupler is used, the energy density runs counter to the size of the Shield Box; therefore, when DUT is inserted, the effects of internal reflection waves can be minimized by securing sufficient space. In addition, when using a fixture or connecting cable inside, measurement errors can be reduced by allowing sufficient working space.

    I/O interface panel, fixture, and antenna coupler

    After selecting a Shield Box, choose the I/O interface panels for DUT; a fixture and an antenna coupler can then be selected for internal environment configuration depending on the measurement purpose.

    Shield Box Models and Sizes

    Manual Operation

    Model NumberSize

    TC-5910D 207(W) x 424(D) x 170(H) mm, lid closed. 435(H) mm, lid open
    TC-5915A 325(W) x 475(D) x 224(H) mm, lid closed. 442(H) mm, lid open
    TC-5916A 400(W) x 480(D) x 240(H) mm, lid closed. 495(H) mm, lid open
    TC-5922A 382(W) x 577(D) x 290(H) mm, lid closed. 680(H) mm, lid open
    TC-5930A/AR 217(W) x 398(D) x 282(H) mm
    TC-5921A 296(W) x 515(D) x 272(H) mm. lid closed. 619(H) mm, lid open
    TC-5970D 662(W) x 698(D) x 530(H) mm
    TC-5972D 562(W) x 642(D) x 446(H) mm
    TC-5977A 914(W) x 940(D) x 869(H) mm

    Pneumatic Operation

    Model NumberSize

    TC-5910DP 211(W) x 410(D) x 193(H) mm, lid closed. 355(H) mm, lid open
    TC-5915AP 325(W) x 432(D) x 233(H) mm, lid closed. 372(H) mm, lid open
    TC-5916AP 420(W) x 430(D) x 260(H) mm, lid closed. 422(H) mm, lid open
    TC-5952C 342(W) x 239(D) x 262(H) mm, lid closed. 410(H) mm, lid open
    TC-5901C 459(W) x 300(D) x 302(H) mm, lid closed. 449(H) mm, lid open
    TC-5922AP 420(W) x 601(D) x 330(H) mm, lid closed. 623(H) mm, lid open
    TC-5972DP 557(W) x 661(D) x 452(H) mm
    Magnetic Operation

    Model NumberSize

    TC-5922AE 382(W) x 560(D) x 290(H) mm, lid closed. 680(H) mm, lid open
    TC-5921AE 296(W) x 515(D) x 272(H) mm, lid closed. 619(H) mm, lid open

     

关键词: